A working smoke detector with a live battery must be installed
on every level of the unit, including in the basement and outside
sleeping rooms. If any members of the family are hearing impaired,
a detector for the hearing impaired must be installed.
|
| • |
The entire unit, both inside and out, including all window
components, must be free of cracking, scaling, peeling, chipping
and loose paint. All defective paint must be scraped, painted
and all paint chips disposed of properly. This prevents exposure
to possible lead-based paint poisoning. |
| • |
If there are four or more consecutive steps (inside or out),
handrails must be securely attached and steps may not be deteriorated.
|
| • |
Porches or decks that are more than 30” above
the ground level must have railings or protective barriers.
|
| • |
Downspouts or gutters that are missing or damaged must be
replaced or repaired. Any damage to the unit caused by this
condition must also be repaired. |
| • |
There cannot be any accumulation of garbage or debris inside
or outside. Multi-family (4+) units must have refuse facilities
provided, such as trashcans with lids, garbage chutes or dumpsters
with lids. |
| • |
No electrical hazards may exist inside or outside the unit
including no loose, hanging, or exposed wires. Light fixtures
and light switches must operate properly. All three-prong outlets
must be wired correctly and will be checked with a three-prong
circuit tester at the time of inspection to assure safety.
|
| • |
All light switches and outlets must have secured plate covers
installed, free from cracks and chips. |
| • |
The main electrical breaker box must have blanks installed
in all empty spaces and have the proper door according to code
requirements. |
| • |
Every room used for living must have either two working outlets
or one working outlet and a permanently installed light fixture.
|
| • |
All windows and doors must be secure when closed and must
be weather tight. |
| • |
All windows and doors accessible from the outside must have
working sturdy locks. Loose or missing striker plates and split
door jambs must be repaired. |
| • |
All windows intended to be opened must be able to open,
stay up on their own or have the spring clips installed to hold
them open. Screens must be provided for windows that open.
|
| • |
All broken or severely cracked windows must be replaced.
|
| • |
Every bedroom must have at least one window that opens.
|
| • |
The bathroom must have either a window that opens or an operable
exhaust fan. |
| • |
If there is a bathroom with a toilet that is not hooked up
to water and sewer lines, it must be repaired. If it is removed,
the drain must be sealed. |
| • |
The hot water tank's pressure relief valve must have
a discharge line extending within 2-6 inches from the floor.
|
| • |
All plumbing fixtures must be in proper working order. All
leaks must be repaired. |
| • |
The flue pipe leading from the furnace and hot water tank
must be installed correctly and must be sealed at the chimney.
|
| • |
All rooms used for living must have an adequate heat source.
Gas furnaces must be vented to the outside. Electric heat sources
must be permanently installed and controlled by a separate thermostat.
The heat source must be adequate to maintain the unit at 68
degrees when the temperature is below freezing.
|
| • |
Furnace filters should be clean. The tenant should be instructed
on replacement of filters. |
| • |
All ceilings, walls, and floors must be strong, sturdy and
in their permanent positions. All holes must be patched.
|
| • |
Floor coverings that are loose, torn, or frayed creating
a tripping hazard must be repaired or replaced.
|
| • |
All appliances, including built-ins, must be in complete
working order. All burners on the stove must have knobs and
operate properly. |
| • |
Holes in the foundation that would lead to pest or water
infiltration must be patched. |
| • |
Basements must be free of major leaks, standing water, and
mold accumulation. |
| • |
All garages or other buildings on the property also must be
maintained according to regulations. |